Komatsu Galeo PC800-8 Shop Manual page 259

Hydraulic excavator
Table of Contents

Advertisement

10 Structure, function and maintenance standard
1) Control method in each mode
P, E mode
Matching point in P, E mode: Rated output point
(Including fan pump absorption horsepower at
fan max. speed)
Model
Mode
P
E
When the load on the pump rises and the pres-
sure rises, the engine speed goes down.
At this time, the pump discharge (Q) is reduced
and the engine speed (N) is set about the rated
output point. If the pressure lowers, the pump
discharge (Q) is increased until the engine
speed is set about the rated output point.
By repeating this control, the engine can always
be used at near the rated output point.
Compared with the P mode, which provides the
maximum output, the E mode lowers the engine
output to provide matching at a point which gives
better fuel consumption efficiency than the P
mode.
The P mode uses the CO cancel so it can gener-
ate a greater discharge (Q) of oil than in the E
mode at high pressure.
PC800, 850-8
PC800-8
PC850-8
370 kW/1,800 rpm
{496 HP/1,800 rpm}
316 kW/1,650 rpm
{423 HP/1,650 rpm}
SEN00386-03
17

Advertisement

Table of Contents
loading

Table of Contents