10 Structure, function and maintenance standard
Operation
When solenoid is de-energized
•
When the signal current does not flow from the
PPC lock switch or swing lock switch, solenoid
(3) is de-energized.
•
For this reason, spool (5) is pushed fully to the
left by spring (6).
•
As a result, the circuit between ports P and A
closes and the pressurized oil from the control
pump does not flow to the actuator.
•
At the same time, the pressurized oil from the ac-
tuator flows from port A to port T, and is then
drained to the tank.
When solenoid is energized
•
When the signal current flows from the PPC lock
switch or swing lock switch to solenoid (3), sole-
noid (3) is energized.
For this reason, spool (5) is pushed to the right
in the direction of the arrow.
As a result, the pressurized oil from the control
pump flows from port P through the inside of
spool (5) to port A, and then flows to the actua-
tor. At the same time, port T is closed, and this
stops the oil from flowing to the tank.
PC800, 850-8
SEN00384-02
1. Connector
2. Movable core
3. Coil
4. Cage
5. Spool
6. Block
7. Spring
51