10 Structure, function and maintenance standard
4) E mode adjustment function
The matching point in control of engine speed
(N) and pump absorption torque (T) in E mode
can be adjusted by operating the machine moni-
tor.
The matching point can be set to 4 levels of E0 –
E3. As the number is increased, fuel efficiency is
improved but production in unit time is de-
creased.
PC800, 850-8
SEN00386-03