Reader Settings; Setconfiguration - Siemens SIMATIC RF650R Configuration Manual

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

10.3.2

Reader settings

This section describes all the commands with which you can control the configuration of the
reader.
10.3.2.1

setConfiguration

This command transfers a configuration to the reader. After confirming the configuration, this
is activated and stored permanently in the flash memory of the reader. To be able to work
with the newly created configuration, you need to restart the reader.
As an alternative, you can also load a configuration that was created using the WBM.
Note that the reply frame of the reader can take up to 20 seconds.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
<id> value_id </id>
<setConfiguration>
<configData>
<![CDATA[value_configData]]>
</configData>
</setConfiguration>
<id> value_id </id>
<resultCode> 0 </resultCode>
<setConfiguration>
<returnValue>
<configID> value_configID </configID>
</returnValue>
</setConfiguration>
Programming via XML interface