Parameter
Parameter
value_id
10.3.2.7

setParameter

This command sets a specific parameter for the reader.
Changes using this command are stored in volatile memory in the configuration of the WBM.
As a result, the reader works with the value specified with "setParameter" but does not
display this in the WBM.
Note that the reply frame of the reader can take up to 20 seconds.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Type
Decimal value
0...9
<id> value_id </id>
<setParameter>
<name> value_name </name>
<value> value_value </value>
<objType> value_objType </objType>
<objName> value_objName </objName>
</setParameter>
<id> value_id </id>
<resultCode> 0 </resultCode>
<setParameter/>
Values
Description
0...4294967295
Unique command identifier
Programming via XML interface