A.3.9

EDIT-BLACKLIST

The black list is processed. The current transponder can be added, all identified
transponders added, individual transponders deleted or all transponders deleted.
Table A- 23
Command
Byte
0, 1
Mean-
DBL
ing
Value
78
Byte
12
Mean-
SOURCE
ing
Value
0
Table A- 24
Reply
Byte
0, 1
Meaning
DBL
Value
0
Table A- 25
Byte
11
12
26
27 ... 88
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
2, 3
4
5
SN
CC
CI
--
'z'
'U'
13
14, 15
16, 17
--
--
--
0
0
0
2, 3
4
SN
CC
--
'z'
Description of the bytes
Description
Mode:
0x00 = add TagID
0x01 = add all "OBSERVED" transponders
0x02 = delete TagID
0x03 = delete all
Reserved (value = 0)
Length of the EPC ID:
0x00 = not addressed
Buffer for up to 62 bytes EPC-ID
A.3 Command and acknowledgement frames
6, 7
8
TDB
DBN_H
1
0
18 ... 21
22, 23
--
--
0
0
5
6, 7
STATUS
TDB
xx
1
9
10
DBN_L
DBL
1
--
24, 25
26
--
IDLENGT
H
0
xx
8
9
DBN_H
DBN_L
--
1
Appendix
11
MODE
xx
27 ... 88
EPC-ID
xx
10
DBL
0