The following tables show possible combinations of the "r/w" and "w" flags with "p" flags and
the meaning of the combination for a memory bank.
The transponder is in the "open" status when it is identified and in the "secure" status when
its access password is verified.
Table 10- 3
w
0
0
1
1
Table 10- 4
r/w
0
0
1
1
Example
Bank
Masking
Action
In the example above "lockMask = 11 1111 0000" (hexadecimal 3F0). This means that only
write access to the memory locations Kill, Access and EPC is possible. The fields for
"lockAction" are "10 1010 0000" (hexadecimal 2A0), which means:
● Kill password
Read and write access is possible from the "secure" status but not from the "open" status.
The access password for the transponder must be known before the Kill password can be
read or modified.
● EPC memory bank
Write access is possible from the "secure" status but not from the "open" status. The
access password must be known before a new ID can be written to the transponder. You
will find more detailed information on "epcGen2LockAction" and "epcGen2LockMask" in
the "EPC Radio Frequency Identity Protocols Standard Specification".
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Possible combinations of the "w" and "p" flags
p
Description
0
Write access to the particular memory bank is possible from both the "open" and
the "secure" status.
1
Write access to the particular memory bank is permanently possible from both the
"open" and the "secure" status, it cannot be locked.
0
Write access to the particular memory bank is possible from the "secure" status but
not from the "open" status.
1
No write access to the particular memory bank is possible.
Possible combinations of the "r/w" and "p" flags
p
Description
0
Read and write access to the particular password is possible from both the "open"
and the "secure" status.
1
Read and write access to the particular password is permanently possible from
both the "open" and the "secure" status, it cannot be locked.
0
Read and write access to the particular password is possible from the "secure"
status but not from the "open" status.
1
No read or write access to the particular memory bank is possible.
Kill PWD
Access PWD EPC Memory TID Memory
(00) 1 1
1 1
(00) 1 0
1 0
Programming via XML interface
1 1
0 0
1 0
0 0
10.3 XML commands
User
Hex string
Memory
value
0 0
3F0
0 0
2A0