Programming via XML interface
10.3 XML commands
Command
<frame>
<cmd>
</cmd>
</frame>
// opt → Optional: Line can be omitted.
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
Parameter
Parameter
value_id
resetType
216
<id> value_id </id>
<resetReader>
<resetType> value_resetType </resetType>
</resetReader>
<id> value_id </id>
<resultCode> 0 </resultCode>
<resetReader/>
Type
Decimal value
0...9
Fixed values
Values
Description
0...4294967295
Unique command identifier
Reset2Factory
Optional
Reboot
Type of reset
Reset2Factory:
Reset to the factory settings and
delete the stored configuration.
Reboot:
Hardware reader reset without de-
leting the stored configuration. After
the restart, communication must be
re-established.
The default is "Reboot".