Heartbeat - Siemens SIMATIC RF650R Configuration Manual

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
Parameter
Parameter
value_id
10.3.1.3

heartBeat

With this command, it is possible to check whether or not the connection is interrupted (e.g.
wire break) or whether the reader is out of operation (e.g. network failure).
After executing the command, the reader blocks connection requests of new clients for 30
seconds. By periodically sending "heartBeat" commands within a period of 30 seconds, you
can make sure that no other unwanted user applications access the reader.
Command
<frame>
<cmd>
</cmd>
</frame>
Reply
<frame>
<reply>
</reply>
</frame>
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 263)".
Parameter
Parameter
value_id
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Type
Decimal value
0...9
<id> value_id </id>
<heartBeat/>
<id> value_id </id>
<resultCode> 0 </resultCode>
<heartBeat/>
Type
Decimal value
0...9
Values
Description
0...4294967295
Unique command identifier
Values
Description
0...4294967295
Unique command identifier
Programming via XML interface