Siemens SIMATIC RF650R Configuration Manual page 170

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Programming via Rockwell controller
9.5 Programming add-on instructions
Results
Select at least as high a number of "TAG_DATA[x]" elements of the data types
(ATTRIBUTES "0x80" and "0x81") as the number of transponders to be expected. Note the
following points when creating the receive buffer "IDENT_DATA"/data type:
● The first element "NUM_IDS" is always of the type "WORD".
● The next element "TAG_DATA" is always of the type "ARRAY". The number of
transponders to be expected ("n") must be entered in the "ARRAY".
The following tables show an example of the structure of the receive buffer
"IDENT_DATA"/data type for the ATTRIBUTES "0x80" and "0x81".
Table 9- 11
ATTRIBUTE "0x80"
Name
NUM IDS
TAG_DATA
TAG_DATA[1]
Reserved
ID_Len
EPC_ID
tagPC
TAG_DATA[2]
...
TAG_DATA[n]
Table 9- 12
ATTRIBUTE "0x81"
Name
NUM MDS
TAG_DATA
TAG_DATA[1]
reserved
ID_LEN
EPC_ID
tagPC
RSSI
MaxRSSI
MinRSSI
channel
antenna
polarization
time
power
170
Type
Comment
WORD
Number of MDS
ARRAY[1..n] of
IID IN I 80
IID_IN_I_80
BYTE
BYTE
Length of EPC ID
ARRAY[1..62] of
EPC-ID
BYTE
WORD
IID_IN_I_80
...
IID_IN_I_80
Type
Comment
WORD
Number of MDS
ARRAY[1..n] of
IID IN I 81
IID_IN_1_81
BYTE
BYTE
EPC length
ARRAY[1..62]of
EPC-ID
BYTE
WORD
BYTE
RSSI value
BYTE
highest RSSI value
BYTE
lowest RSSI value
BYTE
channel; 1..15_ETSI; 1..53:FCC
BYTE
antenna; bit coded;
Bit 0=antenna 1; Bit 1=antenna 2; ...
BYTE
polarizatuin of antenna;
0=undefined; 1=circular; 2=vertical linear;
4=horizontal
Time_OF_Day
S7 time
BYTE
power in dBm