Siemens SIMATIC RF650R Configuration Manual page 124

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Programming via SIMATIC controller
8.5 Programming Ident blocks
Figure 8-10
Table 8- 8
Parameter
DATA
CONFIG_ID
124
"Config_Upload" block
Explanation of the "Config_Upload" block
Data type
Any / Variant
DWord
Description
Data buffer for configuration data.
The real length of the data depends on the com-
plexity of the configuration and the firmware
version of the reader. With a standard configura-
tion of the RF680R/RF685R reader, we recom-
mend a memory size of 4 KB. If you use
advanced reader configurations (filtering) or
want to change the configuration in the future
without needing to adapt the memory size of
"DATA", we recommend a memory size of 8-16
KB.
Note:
For Variant, currently only an "Array_of_Byte"
with a variable length can be created. For Any,
other data types/UDTs can also be created.
Version identifier (4 bytes)
Based on the identifier, you can uniquely identify
the configuration. This is a time stamp in Linux
format.
The time stamp indicates how many seconds
have passed since January 1, 1979, 00:00 (mid-
night). The identifier is assigned when a configu-
ration is generated.
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf685rSimatic rf680r

Table of Contents