Siemens RUGGEDCOM RP110 Installation Manual
Hide thumbs Also See for RUGGEDCOM RP110:

Advertisement

Quick Links

RUGGEDCOM RP110
Installation Guide
6/2014
RC1012-EN-02
Preface
Introduction
Installing the Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RP110

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RP110 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 6/2014 RC1012-EN-02...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3: Table Of Contents

    RUGGEDCOM RP110 Installation Guide Table of Contents Table of Contents Preface ........................ Alerts ..............................v Related Documents ..........................v Accessing Documentation ........................v Training .............................. vi Customer Support ..........................vi Chapter 1 Introduction ......................1.1 Feature Highlights ........................1 1.2 Ports, Controls and Indicator LEDs ....................2 Chapter 2 Installing the Device ....................
  • Page 4 RUGGEDCOM RP110 Table of Contents Installation Guide Chapter 5 Dimension Drawings ..................Chapter 6 Certification ......................6.1 Agency Approvals ........................19 6.2 FCC Compliance ........................19 6.3 Industry Canada Compliance ...................... 19 6.4 EMI and Environmental Type Tests ..................... 20...
  • Page 5: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RP110. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 6: Training

    Siemens sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, please contact Siemens Customer Support through any of the following methods: • Online Visit http://www.siemens.com/automation/support-request...
  • Page 7: Introduction

    Introduction Introduction The RUGGEDCOM RP110 provides the flexibility to power remote PoE devices using standard CAT-5E cable. Converging data and power onto a single cable saves cost, space and labor for new and existing installations. In addition to a power injector, the RP110 has a built in serial server, designed to bridge legacy serial devices on to an IP network.
  • Page 8: Ports, Controls And Indicator Leds

    Chapter 1 RUGGEDCOM RP110 Introduction Installation Guide Key Features • Substation Rated: ▪ IEC 61850-3 ▪ IEEE 1613 ▪ -40 to 85 °C (-40 to 185 °F) operating (no fans) • Industrial Design: ▪ Panel or DIN mounting ▪ Lightweight Cast Aluminum Enclosure ▪...
  • Page 9 RUGGEDCOM RP110 Chapter 1 Installation Guide Introduction Port Status Indicator LEDs These LEDs indicate when ports are active. Port Type Activity Description Link 10Base-T Green (Solid) Link established 10Base-T Green (Blinking) Transmitting/ receiving data Serial Green (Blinking) Transmitting data Serial...
  • Page 10 RUGGEDCOM RP110 Chapter 1 Installation Guide Introduction Ports, Controls and Indicator LEDs...
  • Page 11: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: Connecting Power

    Chapter 2 RUGGEDCOM RP110 Installing the Device Installation Guide Figure 2: DIN Rail Mounting 1. DIN Rail 2. DIN Rail Bracket Pull the release on the bracket down and slide the device onto the DIN rail. Let go of the release to lock the device in position.
  • Page 13: Connecting High Ac/Dc Power

    RUGGEDCOM RP110 Chapter 2 Installation Guide Installing the Device Section 2.2.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a DC power supply terminal block.
  • Page 14: Grounding The Device

    Chapter 2 RUGGEDCOM RP110 Installing the Device Installation Guide This cable connects transient suppression circuitry to chassis ground and must be removed in order to avoid damage to transient suppression circuitry during testing. Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
  • Page 15: Communication Ports

    RUGGEDCOM RP110 Chapter 3 Installation Guide Communication Ports Communication Ports The RP110 comes equipped with a standard IRIG-B port, an RS232/RS422/RS485 pluggable terminal for serial connections, and a 10Base-T Power over Ethernet (PoE) port for connection with RUGGEDCOM WiN devices.
  • Page 16: Rs232 Data Ports

    Chapter 3 RUGGEDCOM RP110 Communication Ports Installation Guide Mode Description RS232 Receive data RS232 Transmit data Shared common RS422/485 Receive data- RS422/485 Receive data+ RS485 Transmit data- RS485 Transmit data+ Figure 7: Serial Terminal Pin Configuration 1. Rx 2. Tx 3.
  • Page 17: Rs485/422 Data Ports

    RUGGEDCOM RP110 Chapter 3 Installation Guide Communication Ports Name Description Receive Data Transmit Data SGND Signal Ground Figure 8: Phoenix-Style DB9 Connector Pin Configuration The RS232 data port has two modes of operations, but only one mode is active at any given time: •...
  • Page 18: Copper Ethernet Port

    Chapter 3 RUGGEDCOM RP110 Communication Ports Installation Guide • The shield should be connected to earth ground at a single point to avoid loop currents. • The twisted pair should be terminated at each end of the chain (typically with a 120 Ohm resistor and a 10nF capacitor in series across the twisted pair).
  • Page 19 RUGGEDCOM RP110 Chapter 3 Installation Guide Communication Ports RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury. The following is the pin-out for the RJ45 male connector:...
  • Page 20 RUGGEDCOM RP110 Chapter 3 Installation Guide Communication Ports Copper Ethernet Port...
  • Page 21: Technical Specifications

    RUGGEDCOM RP110 Chapter 4 Installation Guide Technical Specifications Technical Specifications The following sections provide important technical specifications related to the device and available modules: • Section 4.1, “Power Supply Specifications” • Section 4.2, “Operating Environment” • Section 4.3, “Mechanical Specifications”...
  • Page 22 Chapter 4 RUGGEDCOM RP110 Technical Specifications Installation Guide Parameter Value Ingress Protection IP40 (1 mm or 0.04 in objects) Enclosure Lightweight Cast Aluminum Mechanical Specifications...
  • Page 23: Dimension Drawings

    RUGGEDCOM RP110 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 56.6 11.4 77.2 95.0 Figure 11: Overall Dimensions...
  • Page 24 RUGGEDCOM RP110 Chapter 5 Installation Guide Dimension Drawings...
  • Page 25: Certification

    RUGGEDCOM RP110 Chapter 6 Installation Guide Certification Certification The RP110 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. • Section 6.1, “Agency Approvals” • Section 6.2, “FCC Compliance”...
  • Page 26: Emi And Environmental Type Tests

    Chapter 6 RUGGEDCOM RP110 Certification Installation Guide Section 6.4 EMI and Environmental Type Tests The RP110 has passed the following EMI and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure +/- 8 kV...
  • Page 27 RUGGEDCOM RP110 Chapter 6 Installation Guide Certification Test Description Test Levels Severity Levels AC Power ports 2 kVDC H.V. Impulse DC Power ports 5 kV AC Power ports 5 kV Shielded cable used. IEEE 1613 (C37.90.x) EMI Immunity Type Tests...
  • Page 28 RUGGEDCOM RP110 Chapter 6 Installation Guide Certification EMI and Environmental Type Tests...

Table of Contents