Advertisement

Quick Links

SIMATIC RF662A
SIMATIC Ident
RFID systems
SIMATIC RF662A
Operating Instructions
12/2022
C79000-G8976-C684-01
Characteristics
Ordering data
Installation
Integration into RF600
systems
Antenna patterns
Maximum read/write
ranges
Technical data
Dimension drawing
Approvals & certificates
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RF662A

  • Page 1 SIMATIC RF662A Characteristics Ordering data SIMATIC Ident Installation Integration into RF600 systems RFID systems SIMATIC RF662A Antenna patterns Maximum read/write ranges Operating Instructions Technical data Dimension drawing Approvals & certificates 12/2022 C79000-G8976-C684-01...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Antenna patterns in the FCC frequency band ..............20 Interpretation of directional radiation patterns ..............22 Maximum read/write ranges ....................... 23 Technical data ............................25 Dimension drawing ..........................27 Approvals & certificates ........................29 SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 4 Table of contents SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 5: Characteristics

    The antenna is a broadband antenna and covers the frequency ranges from 865 to 928 MHz. Function The SIMATIC RF662A is used for transmitting and receiving data in the UHF range. The antennas are connected to the SIMATIC RF600 readers via antenna cables that are available in different lengths.
  • Page 6 Characteristics SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 7: Ordering Data

    Ordering data Table 2- 1 RF662A ordering data Product Article number SIMATIC RF662A 6GT2812-1AA08 Table 2- 2 Ordering data accessories Product Article number SIMATIC RF600 antenna holder 3-way kit 6GT2890-2AB10 Connecting cable between 1 m (cable loss 0.5 dB) 6GT2815-0BH10 reader and antenna 3 m (cable loss 1.0 dB)
  • Page 8 Ordering data SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 9: Installation

    • For indoor use only (dry location) • Coaxial connectors and cables shall comply with NFPA70 art. 820 part V Antenna holders The Siemens antenna holder allows fine adjustment of the antenna field by setting the solid angle. SIMATIC RF662A...
  • Page 10 Installation SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 11: Integration Into Rf600 Systems

    4.1.1 Connecting the antenna The SIMATIC RF662A antenna must be connected to the reader using an antenna cable. Preassembled standard cables in lengths of 1 m, 3 m, 5 m, 10 m, 15 m, 20 m and 40 m are available to connect the antenna.
  • Page 12 Requirement Note Use of Siemens antenna cable To ensure optimum functioning of the antenna, it is recommended that a Siemens antenna cable is used in accordance with the list of accessories. Strain relief To protect the antenna or the antenna connector from strain, you can attach strain relief, e.g.
  • Page 13: Bending Radii And Bending Cycles Of The Cable

    • Antenna gain: 7 dBi (10 dBic) • Radiated power: ≤ 2000 mW ERP (or 33 dBm ERP) Converted into EIRP: ≤ 3250 mW EIRP (or 35 dBm EIRP) • Use of cable loss associated with the antenna cable. SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 14 • Conducted power P (dBm) of the RF600 reader: < 30 dBm • Antenna gain G (dBi) in the FCC frequency band: ≤ 6 dBi • Cable loss a (dB): ≥ 1 dB P (dBm) ≤ 30 dBm - (G - 6 dBi) + a SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 15 RF600 systems that are put into operation in Japan must not exceed the following radiated power with an RF662A antenna: • 500 mW EIRP (or 27 dBm EIRP) for operation with RF650R (ARIB STD-T107) • 4000 mW EIRP (or 36 dBm EIRP) for operation with RF680R/RF685R (ARIB STD-T106) SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 16 Integration into RF600 systems 4.2 Antenna parameter assignment SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 17: Antenna Patterns

    (horizontal/vertical) is unimportant. Make sure, however, that the transponder is aligned with the antenna. Figure 5-1 Alignment of the transponder polarization axis with a circular antenna axis of symmetry SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 18: Antenna Patterns In The Etsi Frequency Band

    "Interpretation of directional radiation patterns (Page 22)". Note that the measurements presented graphically below were carried out in a low-reflection environment. Deviations can therefore occur in a normally reflecting environment. SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 19 Radiation diagram (circular) in the ETSI frequency band Pattern of the vertical plane of the antenna Pattern of the horizontal plane of the antenna Figure 5-3 Directional radiation pattern of RF662A in the ETSI frequency band SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 20: Antenna Patterns In The Fcc Frequency Band

    "Interpretation of directional radiation patterns (Page 22)". Note that the measurements presented graphically below were carried out in a low-reflection environment. Deviations can therefore occur in a normally reflecting environment. SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 21 Radiation diagram (circular) in the FCC frequency band Pattern of the vertical plane of the antenna Pattern of the horizontal plane of the antenna Figure 5-5 Directional radiation pattern of the RF662A in the FCC frequency band SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 22: Interpretation Of Directional Radiation Patterns

    50% of the maximum range at ± 40° from the Z axis within the vertical plane (see line shown in blue in the directional radiation pattern: Characteristic of the vertical plane of the antenna and the associated representation of the reference system). SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 23: Maximum Read/Write Ranges

    • Room temperature of approx. 20 - 25 °C • Optimized real measurement conditions (laboratory with few metallic reflecting surfaces) Table 6- 1 Read ranges of the antenna (all ranges in meters [m]) SIMATIC RF662A with SIMATIC SIMATIC SIMATIC RF615R...
  • Page 24 Maximum write ranges The antenna requires more power for writing than for reading data. When writing, the maximum range reduces by approximately 30% - 50% compared with the read range, depending on the transponder used. SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 25: Technical Data

    Technical data Table 7- 1 Technical specifications of the RF662A antenna 6GT2812-1AA08 Product type designation SIMATIC RF662A Radio frequencies Operating frequency 865 to 928 MHz Electrical data Maximum radiated power • ETSI • ≤ 2000 mW ERP • • ≤ 4000 mW EIRP •...
  • Page 26 Proof of suitability • ETSI • CE (ETSI EN 302208) • • FCC (Title 47, Part 15.247), cULus MTBF 1190 years The values for shock and vibration are maximum values and must not be applied continuously. SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 27: Dimension Drawing

    Dimension drawing Figure 8-1 Dimension drawing for RF662A All dimensions in mm SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 28 Dimension drawing SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 29: Approvals & Certificates

    The approval for Industry Canada is granted in association with the Industry Canada approval of the following RF600 readers: • IC: 267X-RF600R2, Model RF650R (for 6GT2811-6AB20-1AA0) • IC: 267X-RF600R2, Model RF680R (for 6GT2811-6AA10-1AA0) • IC: 267X-RF600R2, Model RF685R (for 6GT2811-6CA10-1AA0) SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...
  • Page 30 UL 62368-1 - AVICT Equipment - Part 1: Safety Requirements • CSA C22.2 No. 62368-1-14 AVICT Equipment - Part 1: Saftey Requirements Korea Communications Commission Certificate of Broadcasting and Communication Equipments Republic of Korea SIMATIC RF662A Operating Instructions, 12/2022, C79000-G8976-C684-01...

This manual is also suitable for:

6gt2812-1aa08

Table of Contents