Siemens SIMATIC RF650R Configuration Manual page 122

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Programming via SIMATIC controller
8.5 Programming Ident blocks
Table 8- 5
Parameter
ATTRIBUTE
IDENT_DATA
Results
Table 8- 6
ATTRIBUTE "0x89" ("IID_READER_STATUS_89_RF68xR" data type)
Name
status_info
hardware_version
firmware_version
config ID
inventory_status
sum of filtered tags
filtered_smoothing
filtered_blacklist
filtered data-filter
filtered RSSI thresold
filtered RSSI delta
122
Explanation of the "Reader_Status" block
Data type
Byte
Any / Variant
Type
Comment
BYTE
SLG-Status mode(Subcommand)
BYTE
Version of hardware
ARRAY[1..4] of
Version of firmware
CHAR
DWORD
Unix timestamp
WORD
0=inventory not active;1=inventory active;2=presence
mode active
WORD
All filtered Tags
Filtered Tags trough Smoothing
WORD
Filtered Tags trough Blacklist
WORD
WORD
Filtered Tags trough Data-Filter
WORD
Filtered Tags trough RSSI Threshold
WORD
Filtered Tags trough RSSI Delta
Default values
Description
B#16#81
Identifier of the status mode "0x89"
Note: The default value is not valid for
RF680R/RF685R and needs to be
adapted.
0
Event values depending on attributes
Note:
For Variant, an "Array_of_Byte" with a
variable length and the existing status
UDTs can be created. For Any, other
data types/UDTs can also be created.
Configuration Manual, 03/2018, C79000-G8976-C386-06
SIMATIC RF650R/RF680R/RF685R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf685rSimatic rf680r

Table of Contents