Reading out error messages using the WBM
All the diagnostics messages of the reader are entered in the "Log" if a check mark was set
for "ERRORS" in the WBM configuration in "Settings - General". The log helps SIEMENS
specialists to analyze errors. You will find further information on the "Log" in the section "The
"Diagnostics - Log" menu item (Page 95)".
12.3

Module replacement

Before replacing a module
NOTICE
Backing up the configuration
Prior to replacing the module, make sure that you back up the configuration stored on the
reader so that you can transfer this to the newly connected reader following module
replacement.
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
AutoId
text
READ_
ERROR
WRITE_
ERROR
WRITE_
ERROR
MISC_ERROR_
TOTAL
MISC_ERROR_
TOTAL
DEVICE_NOT_
READY
Error description
Read access to the transponder has failed.
Write access to the transponder has failed.
Writing the EPC-ID on the transponder has failed.
Enabling write protection on the transponder has failed.
The "Kill" command failed.
The specified read point is inactive because it was not
assigned to any antenna.
Service and maintenance
12.3 Module replacement
299