XML/
OPC UA
AutoId
LED
status
status
(hex)
0xA5
good
19
0xA6
good
19
0xA7
good
9
0xA8
good
19
0x41
good
20
0x43
good
20
0x46
OpcUa_
--
BadInva-
lidState
0xC1
good
18
0xCA
good
1
0xCB
OpcUa_
--
BadOutOf
Range /
OpcUa_
Bad
Configura-
tion
Error
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
AutoId
text
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
MULTIPLE_
IDENTIFIERS
RF_COMMUNICATION_
ERROR
DEVICE_FAULT
DEVICE_FAULT
--
INVALID_
CONFIGURATION
MISC_ERROR_
TOTAL
--
Error description
The selected frequency is not enabled.
The carrier signal is not activated.
There is more than one transponder in the transmission
window.
General radio protocol error
Fault in power supply
The power supply is very close to the low limit.
Antenna errors
The antenna or the antenna cable is defective.
•
Error in the connection to the reader; the reader is not
•
answering (in PROFIBUS operation).
–
The cable between the communications module
and reader is wired incorrectly or there is a cable
break
–
The 24 V supply voltage is not connected or is
turned off or has failed briefly
–
Automatic fuse on the communications module
has blown
–
Hardware defective
–
Another reader is in the vicinity and is active
–
There is a reflecting metal surface in the vicinity
that is disrupting the antenna field
–
Execute "init_run" after correcting the error
The command is not permitted in this status or is not
supported.
Possible cause:
"INIT" was chained.
•
Command repetition was started without "Presence
•
mode".
The specified tag field of the transponder is unknown.
General error
No or bad configuration data/parameters were trans-
ferred.
Possible cause:
You are accessing a read point that is not configured.
•
Service and maintenance
12.2 Error messages
297