Programming via SIMATIC controller
8.6 Programming the Ident profile
8.6.4

Commands

Table 8- 22
PHYSICAL-READ
CMD
OFFSET
LEN_
BUFFER
DATA
0x70
Offset in
Length
the
of re-
"RXREF"
ceived
receive
data
buffer
Table 8- 23
PHYSICAL-WRITE
CMD
OFFSET
LEN_
BUFFER
DATA
0x71
Offset in
Length
the
of the
"TXREF"
data to
send
be writ-
buffer
ten
Table 8- 24
READER-STATUS
CMD
OFFSETBUFFER
0x74
Offset in the "RXREF"
receive buffer
142
ADR_TAG
CHAINED EPCID_
Address
True =
on the
chained
tran-
False =
sponder
not
chained
ADR_TAG CHAINED EPCID_
Address
True =
on the
chained
tran-
False =
sponder
not
chained
ATTRIBUTES
Identifier of the status
mode "0x89"
LEN_ID
UID
Buffer for up to
Length of
62 bytes EPC-ID
the EPC-
ID (2-62
2 - 62-byte EPC-
bytes)
ID is entered at
the start of the
0x00 ≙
buffer (length is
unspeci-
set by "LEN_ID")
fied sin-
gle tag
Default value:
access
0x00 ≙ unspeci-
fied single tag
access
LEN_ID
UID
Buffer for up to
Length of
62 bytes EPC-ID
the EPC-
ID (2-62
2 - 62-byte EPC-
bytes)
ID is entered at
the start of the
0x00 ≙
buffer (length is
unspeci-
set by "LEN_ID")
fied sin-
gle tag
Default value:
access
0x00 ≙ unspeci-
fied single tag
access
CHAINED
True = chained
False = not chained
Configuration Manual, 03/2018, C79000-G8976-C386-06
MEM_
PSWD
BANK
Memory
Pass-
bank
word
0x00 ≙
0x00 ≙
no pass-
reserved
pass-
0x01 ≙
word
EPC
0x02 ≙
TID
0x03 ≙
USER
MEM_
PSWD
BANK
Memory
Pass-
bank
word
0x00 ≙
0x00 ≙
no pass-
reserved
pass-
0x01 ≙
word
EPC
0x02 ≙
TID
0x03 ≙
USER
IDENT_
DATA
Received status data
You will find the data struc-
ture of the status mode in the
section "Reader_Status
(Page 121)".
SIMATIC RF650R/RF680R/RF685R
IDENT_
DATA
Read data
IDENT_
DATA
Data to be
written

Hide quick links: