Siemens SIMATIC RF650R Configuration Manual page 295

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

"ER"
XML/
PLC block
LED
LED
(hex)
(hex)
--
0x65
0xE6FE05
--
0x66
0xE6FE06
2 Hz
0xE1
0xE6FE81
2 Hz
0xE2
0xE6FE82
2 Hz
0xE3
0xE6FE83
2 Hz
0xE4
0xE6FE84
2 Hz
0xE5
0xE6FE85
2 Hz
0xE6
0xE6FE86
2 Hz
0xE7
0xE6FE87
2 Hz
0xE8
0xE6FE88
2 Hz
0xE9
0xE6FE89
2 Hz
0xEA
0xE6FE8A
2 Hz
0xEB
0xE6FE8B
2 Hz
0x71
0xE7FE01
--
0x72
0xE7FE02
--
0x73
0xE7FE03
--
0x74
0xE7FE04
--
0x75
0xE7FE05
--
0x76
0xE7FE06
--
0x77
0xE7FE07
--
0x78
0xE7FE08
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Error description
An error has occurred that makes a Reset_Reader ("WRITE-CONFIG" with "Config = 3")
necessary.
Possible causes / action to be taken:
The "WRITE-CONFIG" command is incorrect.
After eliminating the error, execute an "INIT".
Check the "IID_HW_CONNECT" parameter.
The reset timer has expired.
A parameter is missing.
The parameter has an invalid format.
The parameter type is invalid.
Unknown parameter.
The command or the frame has an invalid format.
The inventory command failed.
Read access to the transponder has failed.
Write access to the transponder has failed.
Writing the EPC-ID on the transponder has failed.
Enabling write protection on the transponder has failed.
The "Kill" command failed.
In this status, only the "Reset_Reader" command ("WRITE-CONFIG") is permitted.
The "CMD" command code is not permitted.
The "LEN_DATA" parameter of the command is too long and does not match the global
data reserved within the send data buffer (TXBUF).
The receive data buffer (RXBUF) or the send data buffer (TXBUF) is too small, the buffer
created at TXBUF/RXBUF does not have the correct data types or the parameter
"LEN_DATA" as a negative value.
Possible cause / action to be taken:
Check whether the buffers TXBUF/RXBUF are at least as large as specified in
LEN_DATA.
With S7-1200/1500:
In the Ident profile, only an "Array of Byte" may be created for TXBUF and RXBUF.
In the "Reader_Status" block, only an "Array of Byte" or the corresponding data
types ("IID_TAG_STATUS_XX_XXX" or "IID_READER_STATUS_XX_XXX") may be
created
Error message that informs you that only an "INIT" command is permitted as the next com-
mand. All other commands are rejected.
Wrong index
Permitted index is in the ranges "101 ... 108" and "-20401 ... -20418".
The reader or communications module does not respond to "INIT" ("INIT_ACTIVE" is ex-
pected in the cyclic status message).
The next steps:
Check the address parameter "LADDR".
Timeout during "INIT" (60 seconds according to "TC3WG9")
Service and maintenance
12.2 Error messages
295

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf685rSimatic rf680r

Table of Contents