Killtag - Siemens SIMATIC RF650R Configuration Manual

Ident rfid systems
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Programming via XML interface
10.3 XML commands
Parameter
value_
commandRetry
value_airRetry
value_
filterDataAvailable
10.3.3.11

killTag

With this command, the selected transponder is deactivated. If no EPC-ID is made available
or detected, the command is executed with all the transponders recognized from the read
point.
Note
If no EPC-ID is specified, the results are influenced by all the set filter mechanisms (refer to
the section "The "Settings - Filters" menu item (Page 68)"). Then in the reply frame, only the
transponders that were not filtered out appear. If an EPC-ID is specified, the data filter has
no effect.
The reply frame contains the IDs of all identified transponders. A flag for each transponder
indicates whether or not the command was successful for this transponder.
If no transponder was identified, a negative reply is returned.
254
Type
Values
Decimal value
0...65535
0...9
Decimal value
0...65535
0...9
Fixed values
True
False
Description
Optional
Number of times the reader repeated
commands attempting to obtain correct
data.
"0" corresponds to no attempt.
The maximum number of attempts is
set using the WBM.
Optional
Number of times the reader repeated
air interface commands attempting to
obtain correct data.
"0" corresponds to no attempt.
The maximum number of attempts is
specified in the reader firmware and
cannot be modified.
Optional
Indicates whether or not a filter criteri-
on was received.
True:
No problem All the data was read
or there was no filter set.
False:
Data could not be read.
SIMATIC RF650R/RF680R/RF685R