Procedure for optimizing the antenna alignment
Note
Do not optimize the antenna alignment during operation
We recommend that you do not optimize ( ) the antenna alignment during operation since
this can disturb operation. Optimize the antenna alignment prior to putting the system into
operation.
Basic settings
In this area, you can select the antenna whose alignment needs to be optimized. With the
"Start/Stop adjustment" buttons ( / ), you can control the measurement of the RSSI
values.
By clicking the
selected antenna and the measured values obtained are displayed. Any existing measured
values from a previous measurement are deleted. By clicking the
measurement is stopped.
Transponder list
After you have started measuring the RSSI values, all the transponders identified by the
reader are listed in the table. Select the "EPC-ID in ASCII format" check box to display the
EPC-IDs of the transponders in ASCII code.
Table 7- 21
Property
EPC ID
RSSI
RSSI min.
RSSI max.
Acquisition cycles
Date/time
You can select the transponders individually in the table. The selected transponder is
highlighted in color and its measured values shown in the "RSSI display" area.
By clicking the "Apply" button, you transfer the value entered in the field to the "Radiated
power" input box of the "Settings - Read points" menu item. This change is transferred
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Select the required antenna and start measuring the RSSI values.
Select a transponder from the list.
Transfer the activation power to the "Radiated power" input box of the "Settings - Read
points" menu item.
Adjust the antenna until you obtain the highest possible RSSI value.
button, a new measurement is started. Cyclic reads are performed on the
Displayed properties of the recognized transponders
Description
ID of the identified transponder
Last measured RSSI value of the transponder
Minimum RSSI value of the transponder. Calculated over all successful inven-
tories.
Maximum RSSI value of the transponder. Calculated over all successful inven-
tories.
Number of inventory replies (scans) of this transponder.
Time stamp when the transponder was identified the first time.
Configuring with the WBM
7.3 The menu items of the WBM
button, the