Parameter
rSSIMax
value_channel
value_power
value_polarization
value_inventoried
Value_
filterDataAvailable
value_fieldName
value_bank
value_
startAddress
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Type
Values
Decimal value
0...255
0...9
Decimal value
1...50
0...9
Decimal value
0, 5.00...33.00
0...9
Fixed values
Circular
Vertical
Horizontal
Unknown
Decimal value
0...65535
0...9
Fixed values
True
False
Text
--
--
0...3
Decimal value
0...65535
0...9
Programming via XML interface
10.4 XML EventReports
Description
The highest RSSI value with which the
transponder was detected. This is a
value without a unit and without direct
reference to the power strength.
Optional
Channel number on which the tran-
sponder was detected.
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Polarization of the antenna.
With external antennas always un-
known.
Optional
Indicates how often the transponder
was identified via the air interface be-
fore it changed to the "Observed" sta-
tus.
Optional
Indicates whether or not a filter criteri-
on was received.
True:
No problem. All the data was read
or there was no filter set.
False:
Data could not be read.
Name of tag field
Is specified in the WBM (refer to the
section "The "Settings - Tag fields"
menu item (Page 66)").
Memory bank of the tag field
0: Reserved
1: EPC
2: TID
3: USER MEMORY
Start address of the first byte in the
memory bank where reading will start.