Table 8- 10
Parameter
ATTRIBUTE
DURATION
DUR_UNIT
IDENT_DATA
NUMBER_TAGS
LEN_DATA
Results
Select at least as high a number of "TAG_DATA[x]" elements of the data types
(ATTRIBUTES "0x80" and "0x81") as the number of transponders to be expected. Note the
following points when creating the receive buffer "IDENT_DATA"/data type:
● The first element "NUM_IDS" is always of the type "WORD".
● The next element "TAG_DATA" is always of the type "ARRAY". The number of
transponders to be expected ("n") must be entered in the "ARRAY".
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
Explanation of the "Inventory" block
Data type
Byte
Word
Word
Any / Variant
Int
Word
Programming via SIMATIC controller
Default values
Description
B#16#0
Selecting the status mode
0x80 ≙ EPC-ID without additional
•
information
0x81 ≙ EPC-ID with additional
•
information on the RSSI value and
reserved bytes
0x86 ≙ enable Presence mode
•
0x87 ≙ disable Presence mode
•
W#16#0
Duration dependent on "DUR_UNIT"
Period of time or number of invento-
ries or number of "Observed" events
Example:
0x00 ≙ no inventory or 0 ms
•
0x01 ≙ one inventory or 1 ms or
•
one transponder
W#16#0
Unit for "DURATION"
0x00 ≙ time [ms]
•
0x01 ≙ inventories
•
0x02 ≙ number of "Observed"
•
events
0
Data buffer for inventory data
Note:
For Variant, an "Array_of_Byte" with a
variable length and the existing status
UDTs can be created. For Any, other
data types/UDTs can also be created.
0
Number of transponders in the anten-
na field
W#16#0
Length of the valid data
8.5 Programming Ident blocks
127