Programming via XML interface
10.4 XML EventReports
Parameter
value_rSSI
value_channel
value_power
value_polarization
10.4.1.3

ioEventReport

An I/O event report signals changes at an input or output.
In the WBM, the sending of I/O events can be configured. You will find more information on
events in the section "The "Settings - Communication" menu item (Page 74)".
Report
<frame>
<report>
</report>
</frame>
// opt → Optional: Line can be omitted.
272
Type
Decimal value
0...9
Decimal value
0...9
Decimal value
0...9
Fixed values
<id> value_id </id>
<ioer>
<io>
<ioName> value_ioName </ioName>
<ioEvent> value_ioEvent </ioEvent>
<utcTime> value_utcTime </utcTime>
</io>
<io>
// opt
...
</io>
// opt
</ioer>
Values
Description
0...255
RSSI value
This is a value without a unit and with-
out direct reference to the power
strength.
1...50
Optional
Channel number on which the tran-
sponder was detected.
0, 5.00...33.00
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Circular
Polarization of the antenna.
Vertical
With external antennas always un-
Horizontal
known.
Unknown
Configuration Manual, 03/2018, C79000-G8976-C386-06