Description
3.1 Properties of the UHF readers
Characteristics
The following characteristics distinguish the SIMATIC RF650R, RF680R and RF685R UHF
readers:
Table 3- 1
Characteristics
Antennas
Transmit power (max.)
Digital inputs/outputs
RS-422 interface
PROFIBUS connection
via CM
Ethernet interface
Transmission speed
(max.)
Degree of protection
Configura-
tion/diagnostics options
Interfaces to
PC/controller
The maximum transmit power is restricted depending on the country of use.
1)
NOTICE
IRT is not supported
Note that the RF680R/RF685R readers do not support IRT (Isochronous Real Time). The
readers can also not function as IRT conductors (e.g. in a bus structure).
The readers can be configured as clients in MRP rings. Network diagnostics via SNMP is
supported by the readers.
NOTICE
Operation in VLANs
Note that the readers cannot be operated in VLANs whose ID is ≠ 0.
16
Characteristics of the readers
RF650R
4 x external antenna connectors
--
--
1 x Industrial Ethernet,
RJ-45
100 Mbps
IP30
WBM (browser)
XML interface
(TCP/IP with XML pro-
tocol)
RF680R
4000 mW
1)
4 x digital inputs and 4 x digital outputs
1 x plug M12 8-pin
2 x Industrial Ethernet, M12
WBM (browser)
XML interface
SIMATIC interface
(TCP/IP with XML protocol, OPC UA, Ethernet/IP
or PROFINET capability)
Configuration Manual, 03/2018, C79000-G8976-C386-06
RF685R
1 x internal, adaptive
antenna
1 x external antenna
connector
ASM 456
(115.2 kbps)
100 Mbps
IP65
STEP 7 (S7)
SIMATIC RF650R/RF680R/RF685R