In the "Events" area, you can define events/conditions that cause a digital output to change
to one of the following statuses:
● On
The output is turned on.
● Off
The output is turned off.
● Inverted
The output changes its status starting from the status that is active at the moment the
event occurs.
Click the button
events.
Table 7- 14
Event
Antenna error
Transponder
identified
Input change
Output change
PLC
output change
Note the following properties of the digital ouputs:
● The outputs are only changed once when the event occurs.
The outputs remain set unchanged even when the event is no longer pending.
● Pending events have no effect on the output.
● If an output is changed when an antenna error is detected, this output nevertheless
remains unchanged when the antenna error is eliminated
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
to add new events. Click the button
Description of the events
Description
If an antenna error occurs on the selected antenna, the output changes to the
status specified here.
If a transponder is identified, the output is changed to the state specified here.
If the state at the selected digital input changes, the output is set to the state
specified here.
If the state at the selected digital output changes, the output is set to the state
specified here.
If the state at the selected PLC output changes, the physical output is set to
the state specified here.
RF680R/RF685R only
Configuring with the WBM
7.3 The menu items of the WBM
to remove already specified
73