Displaying Device Information - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.30 Web server
7.30.6

Displaying device information

The most important device information can be displayed with the aid of the Web server.
Displaying information
Click the "Device information" entry in the navigation.
The most important device information is then displayed in the "Device information" area.
Figure 7-32
You can resort the table displayed using the arrow in the column headers.
Identification and status of a component
As with using the STARTER, a system component can also be identified and its status
displayed using the Web server.
Column
Identification
Status
444
Display area: Device information
Description
Allows a drive object to be identified. If the entry "Identify via LED" is displayed in
this column, an LED blink test can be performed on the drive.
As soon as you click the entry "Identify via LED", the Ready LED on the correspond-
ing component of the drive starts to blink and the component can thus be identified.
The current status of the component is in this column (r0196). Meaning:
Red: Fault active
Orange: Maintenance urgently required
Yellow: Maintenance required
Green: Component is OK.
Function Manual, 11/2017, 6SL3097-4AB00-0BP5