Basic information about the drive system
13.8 Know-how protection
Configuring know-how protection
Make the settings for the know-how protection on the "Drive unit know-how protection" tab.
1. Click the "Drive unit know-how protection" tab.
Figure 13-22 Load to file system know-how protection
By default, the "Without know-how protection" option is active. If you really want to store
the data without protection (not recommended), you can exit the dialog box with "OK" or
"Cancel" at this point.
2. If you want to store with protection, activate one of the following options with a mouse
click:
– "Know-how prot. without copy prot."
– "Know-how protection with basic copy protection (permanently linked to the memory
– "Know-how protection with extended copy protection (permanently linked to the
988
Required inputs: "New password" and "Confirm password"
card)"
Required inputs: "New password", "Confirm password" and "Memory card specified
serial number"
memory card and CU)"
Required inputs: "New password", "Confirm password" "Memory card specified serial
number" and "Control unit specified serial number"