Siemens SINAMICS S120 Function Manual page 458

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.30 Web server
3. Click in the line, next to the parameter whose value you wish to change, on the "Change"
button.
A dialog box opens.
Figure 7-43
4. Enter the new parameter value in the "New value" input field. Then click "Confirm" to
confirm the input.
If this value is not possible or not permitted, the dialog box remains open. A message text
is also displayed.
When the entry of a parameter value is successful, the dialog box is closed. The new
parameter value is displayed in the parameter list.
The changed parameter values must be saved to the memory card of the drive. After a
parameter value has been changed, the "RAM to ROM" button is highlighted red.
5. Click on "RAM to ROM".
The RAM content is backed up with all changes made to the parameter values. The
backup can take several seconds. The color of the button changes to green.
458
Changing drive parameters - new value
Function Manual, 11/2017, 6SL3097-4AB00-0BP5