Siemens SINAMICS S120 Function Manual page 65

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Parameterization with STARTER
In the STARTER commissioning tool, the "Motorized potentiometer" parameter screen in the
project navigator under the relevant drive is activated by double-clicking "Setpoint channel" >
"Motorized potentiometer".
Function diagrams (see SINAMICS S120/S150 List Manual)
• 3001
• 2501
• 3020
Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p1030[0...n]
• p1035[0...n]
• p1036[0...n]
• p1037[0...n]
• p1038[0...n]
• p1039[0...n]
• p1040[0...n]
• p1041[0...n]
• p1042[0...n]
• p1043[0...n]
• p1044[0...n]
• r1045
• p1047[0...n]
• p1048[0...n]
• r1050
• p1082[0...n]
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Setpoint channel overview
Internal control/status words - Control word, sequence control
Setpoint channel - Motorized potentiometer
Motorized potentiometer configuration
BI: Motorized potentiometer, setpoint, raise
BI: Motorized potentiometer, setpoint, lower
Motorized potentiometer, maximum speed
Motorized potentiometer, minimum speed
BI: Motorized potentiometer, inversion
Motorized potentiometer start value
BI: Motorized potentiometer, manual/automatic
CI: Motorized potentiometer, automatic setpoint
BI: Motorized potentiometer, accept setting value
CI: Motorized potentiometer, setting value
CO: Motorized potentiometer, speed setpoint in front of the
ramp-function generator
Motorized potentiometer, ramp-up time
Motorized potentiometer, ramp-down time
CO: Motorized potentiometer, setpoint after the ramp-function
generator
Maximum speed
Extended setpoint channel
3.2 Motorized potentiometer
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents