Sample Interconnections - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

13.4.4

Sample interconnections

Example 1: Interconnection of digital signals
Suppose you want to operate a drive via terminals DI 0 and DI 1 on the Control Unit using
jog 1 and jog 2.
Figure 13-12 Interconnection of digital signals (example)
Example 2: Connection of OC/OFF3 to several drives
The OFF3 signal should be connected to two drives via terminal DI 2 on the Control Unit.
Each drive has the two binector inputs, "1st OFF3" and "2nd OFF3". The two signals are
processed via an AND gate to STW1.2 (OFF3).
Figure 13-13 Connection of OFF3 to several drives (example)
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Basic information about the drive system
13.4 BICO technology: Interconnecting signals
953