11.3.10.2

PROFIenergy commands

Principle of operation
At the start and end of pauses, the plant operator activates or deactivates the pause function
of the plant/system after which the IO controller sends the PROFIenergy "START_Pause" /
"END_Pause" command to the PROFINET devices. The device then interprets the content of
the PROFIenergy command and switches off or on again.
You can call up device information via additional PROFIenergy functions. You can use these
to transfer the "START_Pause"/"END_Pause" command in plenty of time.
PROFIenergy control commands
Control commands
START_Pause
START_Pause_with_time_response Switches from the operating state to the energy-saving mode
END_Pause
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
11.3 Communication via PROFINET IO
Description
Switches from the operating state to the energy-saving mode
depending on the pause duration.
Switches from the energy-saving mode to the operating state
depending on the pause duration.
and also specifies the transition times in the command re-
sponse.
Switches from the energy-saving mode to the operating state.
Cancels a switch from the operating state to the energy-saving
mode.