Siemens SINAMICS S120 Function Manual page 453

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

5. Select the drive object in the "DO" drop-down list.
Figure 7-39
6. Enter the parameter of the drive object in the following input fields (e.g. 601:0).
– First field: Parameter number
– Second field: Index
– Third field: Bit number
The parameter name is now displayed on the right of the input fields. If the parameter
requires no index or bit, the fields remain empty.
7. Click the "Add" button in the parameter list to the right of the first free line.
The parameter is now inserted in the parameter list.
8. Repeat steps 5 to 7 for each parameter that you want to create in the parameter list.
9. Click the "Save list" button to save the parameter list to the memory card of the drive
(OEM/SINAMICS/HMI/PARLISTS).
A new tab is created for the new parameter list. The name of the parameter list appears
in the tab. You can view the actual parameter values and change them when required via
this tab.
10.If you wish to change the order of parameters within the current parameter list, you have
two options:
– Move a selected parameter to the desired position in the list using the "UP" and
– Drag and drop a selected parameter to the desired position in the list.
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Drive parameters – creating a parameter list
"DOWN" buttons".
Basic functions
7.30 Web server
453

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents