Stratum 3 Clock LED Indicators — Continued
Card
LED Label
PAI
ST B
CI
FAIL
ST3
FAIL
ST3
LOCK
ST3
HOLDOVER
ST3
FREE RUN
TOC
FAIL
A
TOC
PORT ALM
A

Verify Timing to the Media Server

1
To administer the Stratum 3 clock, type change synchronization and press
2
Type 3 in the stratum field.
Type the port network number where the TN780 Tone-Clock circuit packs reside in the
3
port network field.
NOTE:
Wait 1 minute for the software to reconfigure the media server synchronization.
Verify the results of test 649. If test 649 fails with a code of 2101, then check the wiring
4
for EXTSYN0 and EXTSYN1. Refer to the maintenance book for your configuration
If test 649 is successful, then the media server is getting correct timing from the Stratum 3
clock.

Resolve Alarms

As a last step, inspect the alarms log.
Use the media server web interface.
1
Click on View Current Alarms and see if any alarms were generated. If so, resolve any
alarms that may exist using the maintenance book for your configuration
Procedure
Replace the ST3 card
Check wiring for its associated DS1 reference and replace the
circuit pack if necessary
Replace the circuit pack
Ignore this LED
Ignore this LED
Ignore this LED
Replace the circuit pack
Replace the circuit pack if necessary