Testing The Complete Configuration; Task List: Test The Configuration - Avaya S8700 Manual

Installing forip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Testing the Complete Configuration

This section provides tests for the complete configuration, including the control and bearer
networks and the telephones and consoles.
This section provides tests to:
review the status of the configuration
test the duplication link to the media servers
test the IP server interfaces, expansion interfaces, and TDM buses in the port networks.
test the telephones and other equipment.
These tests verify that the Time Division Multiplexing (TDM) cables, terminators, and the
Inter-Cabinet Cables (MCC1 Media Gateway) work. If a FAIL Result code is seen, check these
cables. If problems persist, refer to the maintenance book for your configuration
See
''LED Indicators'' on page 178
media servers, Cajun Ethernet switch(es), UPSs, and different circuit packs.
NOTE:
Circuit pack positions are usually given by cabinet, carrier, and slot. They may also be
given by port. The term "cabinet" refers to an MCC1 Media Gateway, making up one to
five port networks, or a stack of SCC1 Media Gateways or 4 G600 Media Gateways in a
rack, making up one port network. A port network is defined as a group of media gateways
or carriers connected together with one TDM bus.

Task List: Test the Configuration

!
CAUTION:
To prevent unnecessary trouble tickets, do not enable the alarms (Alarm Origination
feature) until all installation and administration procedures are completed.
1
''LED display indicating connectivity status'' on page 186
2
''Check Circuit Pack Configuration'' on page 190
''Test Media Server Interchange'' on page 191
3
4
''Test the IPSI Circuit Pack'' on page 192
''Test Expansion Interface Circuit Packs (S8700 Multi-Connect only)'' on page 192
5
''Test Time Division Multiplexing Bus for Each Port Network'' on page 193
6
7
''Test Expansion Interface Exchange for Each Port Network (S8700 Multi-Connect
only)'' on page 194
8
''Save Translations, if Required'' on page 195
''Save Translations, if Required'' on page 195
9
for information regarding the LED status indicators for the