144
Installing the S8700 IP Connect
Install External Ringing
Connections for external ringing are at an information outlet. The media gateway side of the
Main Distribution Frame (MDF) is connected to a TN2183 (or equivalent) Analog Line circuit
pack. The circuitry and power source for the device are customer-provided.
NOTE:
A maximum of 3 devices can connect to 1 analog line circuit pack port.
Wire the ringing device to the information outlet as shown in
1
Modularity'' on page 144
Administer per the Administrator's Guide for Avaya MultiVantage Software.
2
3-Pair and 4-Pair Modularity
Figure notes
1. Port Circuit Pack
2. Media Gateway Connector Pins
(3-Pair Modularity)
3. Main Distribution Frame (MDF)
Pins (3-Pair Modularity)
and
''Example Adjunct Power Connections'' on page
4. Input to Information Outlet
(4-Pair Modularity)
5. Adjunct Power
6. Output From Information Outlet
(4-Pair Modularity)
7. Voice or Data Terminal Pins
May 2002
''3-Pair and 4-Pair
120.