Connecting / Replacing The Control Panel Battery; Important Installation Notes - Pyronix ENFORCER Installation Manual

Hide thumbs Also See for ENFORCER:
Table of Contents

Advertisement

3.4 Connecting / Replacing the Control Panel Battery

1. Unscrew the battery
compartment
NOTE: The Enforcer back up battery must be replaced by the
manufacturer's recommendation. The part code for this battery is BATT9V6/2Ah1-WE.
The battery is NiMH 8 cell 2200mAh rechargeable.
Install the batteries in the space provided and connect the battery connector to the
two pins as shown above. Reinstall the battery holder cover and dispose of the batteries in
accordance with the local regulations.

3.5 Important Installation Notes

Ensure wiring is done to the national wiring regulations in the country where the installation is
taking place. In the UK, this is BS 7671 Requirements for electrical installations; IET Wiring
Regulations (17th edition). If in doubt, consult a local qualified electrician.
Ensure that a readily accessible disconnect device incorporated in the premises installation wiring
shall be provided external to the equipment with a contact separation of at least 3,0mm and
connected as closely as possible to the supply.
Ensure that the Input and Output Board (I/O Board) used to connect wired keypads, readers,
inputs and outputs to the Enforcer, and is only connected to circuits operating at SELV voltage.
When securing external wires, ensure that means are provided in the installation to prevent the
SELV or signal circuits from coming into contact with live parts of the power supply circuit. Wires
should be fixed near their terminal blocks.
The end of stranded conductor shall not be consolidated by soft soldering at places where the
conductor is subjected to contact pressure.
On completion of wiring use tie-wraps to prevent any loose wires causing a safety hazard (material
of cables tie shall be rated at least HB or better).
Cables ties and hoses shall be separate for power supply cable and SELV wirings.
Size of protective bonding conductors: minimum section 1.5mm².
Enforcer: Installation Manual
2. Connect the battery pack
Page: 7
3. Close the battery
compartment masking sure no
battery cable is trapped
underneath.

Advertisement

Table of Contents
loading