Fan Tray 1 Fan 19
Fan Tray 1 Fan 20
Fan Tray 1 Fan 21
user@host>
Two fan tray controller models and their associated fan trays are available. See
Table 10: Fan Tray Controller Specifications
Specification
Corresponding fan tray model
Chassis supported
Introduced in Junos OS Release
Height
Width
Depth
Weight
Airflow Direction in the MX10008 Router
The air intake to cool the chassis is located on the port (line card) side of the chassis. Air flows into the
chassis from the ports in the RCBs and line cards, through the switch fabric boards (SFBs), and exits from
the fan trays and the power supplies. This airflow is called port-to-FRU cooling or airflow out (AFO). See
Figure 23 on page
52.
OK
7800
OK
6450
OK
7650
JNP10008-FAN-CTRL
JNP10008-FAN
Enhanced or standard
15.1X53-D30
1.5 in. (3.81 cm)
6.5 in. (15.24 cm)
9.3 in. (23.62 cm)
1.5 lb (0.68 kg)
Spinning at normal speed
Spinning at normal speed
Spinning at normal speed
Table 10 on page
JNP10008-FTC2
JNP10008-FAN2
Enhanced or standard
19.2R1
1.5 in. (3.81 cm)
6.5 in. (15.24 cm)
9.4 in. (23.88 cm)
1.1 lb (0.5 kg)
51
51.