13. Squeeze the two sides of the power cord retainer clip and insert the ends of the clip into the holes in
the bracket on each side of the AC appliance inlets on the AC power supply faceplate. See
Figure 99 on page
203.
14. Locate two power cords shipped with the router; the cords have plugs appropriate for your geographical
location.
15. Insert the power cord coupler into the power supply.
Each AC power supply has two independent 16 A rated AC inlets on the faceplate. Each inlet must be
connected to a dedicated AC power feed to achieve 2n source redundancy. If redundancy is not a
requirement, use the default input INP1 for a single connection.
16. Fasten the cord retainer by lowering the clip over the cord and pushing the cord into the adjustment
nut of the cord retainer. Rotate the nut until it is tight against the base of the cord. See
Figure 99 on page
203.
Figure 99: Power Cord and Retainer Clip
1
Enable switch for INP1 appears as INP0 in output.
WARNING:
or drape where people can trip on them.
17. If the AC power source outlets have a power switch, set them to the on (|) position.
18. Move the enable switches for input 1 and input 2 to the ON position.
Ensure that the power cords do not block access to router components
2
Enable switch for INP2 appears as INP1 in output.