Juniper MX10008 Hardware Manual page 215

Universal routing platform
Table of Contents

Advertisement

1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the ESD point on the chassis. There is an ESD point located next to the protective earthing terminal
and below PSU 5 on the MX10008 rear panel (see
MX10016 (see
Figure 113 on page
Figure 112: ESD Point on an MX10008 Chassis Rear
1
ESD point
Figure 113: ESD Point on an MX10016 Chassis Rear
1
ESD point
2. Make sure that the voltage across the DC power source cables leads is 0 V and that there is no chance
that the cable leads might become active during the removal process.
3. Ensure the black power supply output switch, to the right of the captive screw, is set to the standby
position.
4. Unscrew the captive screw counterclockwise by using the Phillips (+) screwdriver, number 1.
Figure 112 on page
217).
217) and below PSU_9 on the
217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents