Leuze electronic CML 720i Ex Operating Instructions Manual page 97

Measuring light curtain
Table of Contents

Advertisement

Status (group 14)
Information on the status of the light curtain.
Parameter
Device status
R
error field
X
K
error field
X
Leuze electronic
Index
Sub-
Data
Access
(hex.)
index
type
2162
t16S
RO
2600
t16U
RO
2601
t16U
RO
CML 720i Ex
Starting up the device - CANopen interface
Min.
Max. value
Default Explanation
value
0: Normal function
1: Teaching error
2: Internal temperature/volt-
age monitoring
3: Invalid configuration
4: Hardware error
5: 24 V voltage error (supply
voltage U
6: Transmitter and receiver
incompatible
7: No connection to transmit-
ter
8: Soiling
9: Teaching necessary
10: Measurement not active.
The device
11: Frequency of trigger sig-
nal too high
For internal diagnosis only
For internal diagnosis only
)
B
• reconfigures itself
• (re)starts
• waits for the first trigger
pulse
• was manually stopped