1
2
Figure 4.10: Simple cascading with two light curtains for height monitoring
• Multiple light curtains in a rectangular frame, e.g., for object measurement of height and width along
a transport system.
3
1
2
3
Figure 4.11: Simple cascading with three light curtains for object measurement
The selection of activation via an internal or external trigger signal is made via the respective
fieldbus interface (see chapter 9 et seq.) or via the
chapter 12).
NOTICE
Cascading necessary for multiple-track transport systems!
Cascade light curtains for multiple-track transport systems.
Prevent mutual interference through sequential activation of the light curtains.
If the spatial configuration excludes mutual interference, multiple light curtains can also be activated
simultaneously.
Leuze electronic
Light curtain 1
Light curtain 2
2
Light curtain 1
Light curtain 2
Light curtain 3
2
1
1
Sensor Studio
CML 720i Ex
Functions
configuration software (see
32