Starting up the device - IO-Link interface

The configuration of an IO-Link interface involves the following steps on the receiver control panel and the
IO-Link master module of the control-specific configuration software.
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor-
rectly.
• The basic configuration has been performed (see chapter 8).
9.1
Defining IO-Link device configurations on the receiver control panel
The parameters for the IO-Link interface are configured with the bit rate and process data length (PD
length) configurations. By changing the bit rate and/or the process data length, the light curtain receives a
new IO-Link device ID and must be operated with the compatible IO Device Description (IODD).
NOTICE
Changes take effect immediately!
 The changes take effect immediately (without restarting).
 The IODD file is supplied with the device and is available for download at www.leuze.com.
Factory settings:
Bit rate (COM2) = 38.4 kbit/s
PD length: 2 bytes
The structure of these configurations in the receiver control panel menu is as follows:
Level 0
Level 1
Main Settings
Commands
Operational setting
IO-Link
 Select Main Settings > IO-Link > Bit rate.
 Select Main Settings > IO-Link > PD-Length.
The bit rate and PD length are configured.
Other possible configuration steps are performed via the
chapter 12).
Process mode is configured via the IO-Link master module of the control-specific software.
9.2
Defining configurations via the IO-Link master module of the PLC-specific software
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor-
rectly.
• The basic configuration has been performed (see chapter 8).
• IO-Link-specific basic configurations have been performed.
• IO-Link bit rate selected
• IO-Link PD length selected
Leuze electronic
Level 2
Description
Bit rate
COM3: 230.4
PD Length
2 bytes
Data storage
Deactivated
Activated
Sensor Studio
CML 720i Ex
Starting up the device - IO-Link interface
COM2: 38.4
8 bytes
32 bytes
configuration software (see