6.3

Fastening via sliding blocks

By default, transmitter and receiver are delivered with two sliding blocks (three sliding blocks for measure-
ment field lengths of more than 2,000 mm) each in the side groove (see chapter 17).
 Fasten transmitter and receiver to the machine or system via the lateral T-groove with M6 screws.
Sliding in the direction of the groove is possible, but turning, tilting and pitching is not.
Figure 6.3:
Mounting via sliding blocks
6.4
Fastening via swivel mount
When mounting with the BT-2R1 swivel mount (see table 17.8), sold separately, the light curtain can be
aligned as follows:
• Sliding through the vertical threaded holes in the wall plate of the swivel mount
• Turning by 360° around the longitudinal axis by fixing on the screw-on cone
• Tilting around main axis
• Pitching through horizontal threaded holes in the wall mounting
The wall mounting through threaded holes makes it possible to lift the mounting bracket after the screws
have been loosened over the connection cap. Therefore, the mounting brackets do not need to be
removed from the wall when exchanging the device. Loosening the screws is sufficient.
Figure 6.4:
Mounting via swivel mount