Leuze electronic CML 720i Ex Operating Instructions Manual page 106

Measuring light curtain
Table of Contents

Advertisement

Configuring light curtain 1:
 Configure the trigger settings (triggered, master, total cycle time).
Cascading configuration
(group 7)
 Configure the digital IOs (pin 5) settings.
Digital IO1 (pin 5) settings
(group 10)
Configuring light curtain 2:
 Configure the trigger settings (triggered, slave, delay time).
Cascading configuration
(group 7)
 Configure the digital IOs (pin 5) settings.
Digital IO1 (pin 5) settings
(group 10)
Configuring light curtain 3:
 Configure the trigger settings (triggered, slave, delay time).
Cascading configuration
(group 7)
 Configure the digital IOs (pin 5) settings.
Digital IO1 (pin 5) settings
(group 10)
Leuze electronic
Index 73, bit offset 56
= 1
Index 73, bit offset 48
= 1
Index 73, bit offset 32
Index 81, bit offset 24
= 0
Index 81, bit offset 16
= 0
Index 81, bit offset 00
= 3
Index 73, bit offset 56
= 1
Index 73, bit offset 48
= 0
Index 73, bit offset 00
Index 81, bit offset 24
= 1
Index 81, bit offset 16
= 0
Index 81, bit offset 08
= 1
Index 73, bit offset 56
= 1
Index 73, bit offset 48
= 0
Index 73, bit offset 32
Index 81, bit offset 24
= 1
Index 81, bit offset 16
= 0
Index 81, bit offset 08
= 1
CML 720i Ex
Cascading: active
Note: With cascading operation, the master must also be set to 1 (active)!
Function type: master - sends trigger signal
Master cycle time: total cycle time of all light curtains (LC1+LC2+LC3)
Duration of a TRIGGER cycle in ms
Pin 5 - input/output selection: output
Pin 5 - switching behavior: light switching
Pin 5 - output function: trigger output
Cascading: active
Note: With cascading operation, the master must also be set to 1 (active)!
Function type: slave - expects trigger signal
Delay time Trigger → Scan [µs]: enter cycle time of light curtain 1 (LC1)
Pin 5 - input/output selection: input
Pin 5 - switching behavior: light switching
Pin 5 - output function: trigger input
Cascading: active
Note: With cascading operation, the master must also be set to 1 (active)!
Function type: slave - expects trigger signal
Delay time Trigger → Scan [µs]: enter cycle time of light curtain 1 and light
curtain 2 (= sum of the cycle times of light curtains LC1+LC2)
Pin 5 - input/output selection: input
Pin 5 - switching behavior: light switching
Pin 5 - output function: trigger input
Example configurations
106

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents