Connection And Interconnection Cables - Leuze electronic CML 720i Ex Operating Instructions Manual

Measuring light curtain
Table of Contents

Advertisement

7.2

Connection and interconnection cables

Use only the cables listed in the accessories (see chapter 17) for all connections (connection
cable, analog/IO-Link/fieldbus interconnection cable, cable between transmitter and receiver).
Use only shielded cables for the cable between transmitter and receiver.
NOTICE
Competent persons and approved purpose!
 Only allow competent persons to perform the electrical connection.
 Select the functions so that the light curtain can be used as intended (see chapter 2.1).
7.3
Device connections
The light curtain is provided with the following connections:
Device con-
nection
X1 on receiver M12 connector,
X2 on receiver M12 socket,
X3 on
transmitter
7.4
Digital inputs/outputs on connection X1
Ex works, input/output IO 1 (pin 2) is assigned the teach-in function and input/output IO 2 (pin 5)
is assigned the trigger-in function.
10k
X1-2/5
X1-3
Figure 7.4:
Digital input/output schematic diagram
NOTICE
Single assignment of input functions!
 Each input function may only be used one time. If multiple inputs are assigned the same function, mal-
functions may occur.
7.5
Electrical connection – CML 720i Ex with CANopen or IO-Link interface
The electrical connection is established in the same way for all devices.
Leuze electronic
Type
8-pin
4-/5-pin
M12 connector,
5-pin
10k
Function
Control interface and data interface:
• Voltage supply
• Switching outputs and control inputs
Configuration interface
• Synchronization interface
(for devices with fieldbus interface)
Synchronization interface and fieldbus interface:
• Fieldbus interface (for CANopen and IO-Link devices)
Synchronization interface (for all controller types)
CML 720i Ex
Electrical connection
18 - 30 VDC
X1-1
100 mA (max. 250 mA)
X1-6/7
GND
X1-3
51