Leuze electronic CML 720i Ex Operating Instructions Manual page 69

Measuring light curtain
Table of Contents

Advertisement

Parameter
Manufacturer name
Manufacturer text
Product name
Product ID
Product text
Serial number
Receiver
Hardware version
Firmware version
User-specific name
Device status
Receiver part no.
Transmitter product
designation
Transmitter part no.
Transmitter serial
number
Device characteristics
Beam spacing
Number of physical indi-
vidual beams
Number of configured
logical individual beams
Segment number of a
beam-stream with 16
beams
Device cycle time
Leuze electronic
Index
Sub-
Data type
index
16
0
string
32 bytes
17
0
string
64 bytes
18
0
string
64 bytes
19
0
string
20 bytes
20
0
string
64 bytes
21
0
string
16 bytes
22
0
string
20 bytes
23
0
string
20 bytes
24
0
string
32 bytes
36
0
unsigned 8
64
0
string
20 bytes
65
0
string
64 bytes
66
0
string
20 bytes
67
0
string
16 bytes
68
0
record 80 bit,
isolated
access to
sub-index not
possible
68
1
unsigned 16
(bit
offset
= 64)
68
2
unsigned 16
(bit
offset
= 48)
68
3
unsigned 16
(bit
offset
= 32)
68
4
unsigned 16
(bit
offset
= 16)
68
5
unsigned 16
(bit
offset
= 0)
Starting up the device - IO-Link interface
Access
Value range
Default Explanation
RO
RO
RO
RO
RO
RO
RO
RO
RW
***
R
0 ... 4
RO
RO
RO
RO
RO
RO
5, 10, 20, 40
5
RO
16
RO
16
RO
1
RO
1000
CML 720i Ex
Leuze electronic GmbH + Co. KG
Leuze electronic - the sensor people
Receiver type designation
Order number of the receiver (8-digit)
"Measuring light curtain CML 720i"
Serial number of the receiver for unique product
identification
Device designation defined by the user
Value: 0 device is OK
Value: 1 maintenance required
Value: 2 outside of specifications
Value: 3 function test
Value: 4 error
Order number of the receiver (8-digit)
Type designation
Order number of the transmitter (8-digit)
Transmitter serial number for unique product iden-
tification
The device characteristics specify the beam spac-
ing, the number of physical/logical individual
beams, the number of cascades (16 individual
beams) in the device and the cycle time.
Distance between two adjacent optical individual
beams.
The number of logical individual beams is depen-
dent on the selected operating mode.
The evaluation functions of the CML 700i are cal-
culated on the basis of the logical individual
beams.
The CML 700i has a modular structure. 16 or 32
individual beams are always grouped into a cas-
cade.
The device cycle time defines the duration of a
measurement cycle of the CML 700i.
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents