Pin 5 - Input/output selection
Pin 5 - Switching behavior
Pin 5 - Output function
Configuring light curtain 3:
 Configure the trigger settings (triggered, slave, delay time).
Cascading configuration
Cascading
Function type
Trigger delay time → Scan [us]
 Configure the digital IOs (pin 5) settings.
Digital IO1 (pin 5) settings
Pin 5 - Input/output selection
Pin 5 - Switching behavior
Pin 5 - Output function

11.6.2 Configuration of a cascading arrangement via IO-Link interface

CML700i frame arrangement for cascading with IO-Link interface wiring
3
1
4
4
1
2
3
4
5
Leuze electronic
1: Input
0: Light switching
1: Trigger input
1: Active
Note: With cascading operation, the master must also be set to 1 (active)!
0: Slave (expects trigger signal)
Enter cycle time of light curtain 1 and light curtain 2 (= sum of cycle times of light curtains LC1+LC2)
1: Input
0: Light switching
1: Trigger input
2
1
5
Receiver
Transmitter
Interconnection cable 5 m (see table 17.3)
Connection cable 5 m (see table 17.4)
Interconnection cable 2 m (see table 17.3)