Table 13.6:
Error
RxS 0x3000
RxS 0x3001
RxS 0x3002
RxS 0x3003
RxS 0x3005
RxS 0x3006
RxS 0x3007
RxS 0x3008
RxS 0x3009
RxS 0x300A
RxS 0x3100
RxS 0x3101
Leuze electronic
Serious errors (cannot be corrected)
Description
Hardware error, no details available
Hardware error, transmitter 9V supply
Hardware error, transmitter 5V supply
Hardware error, receiver 5V supply
Hardware error, receiver cascade
No receiver cascade or different LED number of transmitter
and receiver
Hardware error, transmitter
Hardware error, inter-controller communication is inter-
rupted
Hardware error, different number of diodes at transmitter
and receiver
Hardware error, no Rx cascades
Hardware error, no Tx cascades
Error in the factory settings. Can only be rectified by repro-
gramming the device firmware.
CML 720i Ex
Troubleshooting
Measures
Return device following
consultation with Service
department (see
chapter 15)