Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Leuze electronic Manuals
Security Sensors
MLD 300
Original operating instructions
Leuze electronic MLD 300 Original Operating Instructions
Multiple light beam safety devices
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
page
of
118
Go
/
118
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 About this Document
Used Symbols and Signal Words
Checklists
2 Safety
Approved Purpose and Foreseeable Improper Operation
Proper Use
Using the Laser Alignment Aid
Foreseeable Misuse
Competent Persons
Responsibility for Safety
Exemption of Liability
3 Device Description
Device Overview
Connection System
AS-I Parameter Port
Display Elements
Operating Indicators on the Transmitter
Operation Indicators on the Receiver
7-Segment Display at the Receiver
Multicolor Indicator
Integrated Laser Alignment Aid
4 Functions
Start/Restart Interlock
Contactor Monitoring
Signal Output
Range Shift
Multiscan Mode
Periodic Function Test
Muting
Timing Controlled 2-Sensor Muting
Sequence Controlled 2-Sensor Muting
Timing Controlled 4-Sensor Muting
Muting Timeout
Muting Restart
Alternative Connection for Second Muting Signal
Muting-Enable
Partial Muting
Muting Operating Modes
5 Applications
Access Guarding
6 Mounting
Arrangement of Transmitter and Receiver
Arrangement of 1-Beam Safety Sensors
Beam Heights and Ranges
Calculating the Safety Distance
Calculation of the Safety Distance for Vertical Protective Fields with Reaching over
Minimum Distance to Reflective Surfaces
Preventing Mutual Interference between Adjacent Devices
Arrangement of the Muting Sensors
Basic Information
Selecting Optoelectronic Muting Sensors
Minimum Distance for Optoelectronic Muting Sensors
Arrangement of the Muting Sensors for Timing Controlled 2-Sensor Muting
Arrangement of the Muting Sensors for Sequence Controlled 2-Sensor Muting
Arrangement of the Muting Sensors for Timing Controlled 4-Sensor Muting
Mounting the Safety Sensor
Suitable Mounting Locations
Swivel Mount (Optional)
BT-P40 Clamp Bracket (Optional)
7 Electrical Connection
Pin Assignment Transmitter and Receiver
Standard Pin Assignment
AS-I Pin Assignment
AS-I Signal Assignment
Selecting Contactor Monitoring and Start/Restart Interlock
Selecting the Muting Operating Modes
Operating Mode 1 (Muting)
Operating Mode 2 (Muting Timeout 8 H)
Operating Mode 3 (Sequence Controlled 2-Sensor Muting)
Operating Mode 4 (Sequence Controlled 2-Sensor Muting with Muting Timeout 8 H)
Operating Mode 5 (Muting-Enable)
Operating Mode 6 (Partial Muting)
8 Setting the Device into Service
Switching on
AS-I Connection Start-Up
Initial Start-Up
Exchange of AS-I Slaves
Aligning the Safety Sensor
Aligning Without Integrated Laser Alignment Aid
Aligning with Integrated Laser Alignment Aid
Required Devices and Tools
Aligning Without UDC Device Columns and Without UMC Deflecting Mirror Columns
Aligning with UDC Device Columns and with UMC Deflecting Mirror Columns
Start/Restart Button
Unlocking Start/Restart Interlock
Muting Restart
9 Testing
Before the Initial Start-Up and Following Modifications
Checklist - before the Initial Start-Up
To be Performed Periodically by Competent Persons
To be Performed Daily by the Operator
Check List - Daily or at Change of Shift
Annual Testing of Safe Switch-Off of the AS-I Connection
10 Maintenance
11 Rectifying the Fault
What to Do in Case of Failure
Operating Displays of the Leds
Error Messages 7-Segment Display
Multicolor Indicator
Error Message Query Via AS-Interface
12 Disposing
13 Service and Support
14 Technical Data
General Specifications
Dimensions, Weights
Dimensional Drawings: Accessories
15 Ordering Information and Accessories
16 EC Declaration of Conformity
Advertisement
Quick Links
1
Error Messages 7-Segment Display
Download this manual
MLD 300, MLD 500
Multiple Light Beam Safety Devices
O r i g i n a l o p e r a t i n g i n s t r u c t i o n s
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the MLD 300 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Leuze electronic MLD 300
Security Sensors Leuze electronic MLC 500 Series Safe Implementation And Operation
Safety light curtains (60 pages)
Security Sensors Leuze electronic MLC 500 Original Operating Instructions
Safety light curtains (69 pages)
Security Sensors Leuze electronic MLC 520 Operating Instructions Manual
Safety light curtains (65 pages)
Security Sensors Leuze electronic MLD 500 Original Operating Instructions
Multiple light beam safety devices (118 pages)
Security Sensors Leuze electronic MLC 510 AS-i Host/Guest Safe Implementation And Operation
Safety light curtains (59 pages)
Security Sensors Leuze electronic MLC 300 Series Manual
Ip protective tube for mlc safety light curtains (31 pages)
Security Sensors Leuze electronic RSL 430 Original Operating Instructions
Safety laser scanner (127 pages)
Security Sensors Leuze electronic CU411-RS4 Supplement To Original Operating Instructions
Rs4 compability set for rsl 410 and 420 (58 pages)
Security Sensors Leuze electronic SOLID-2 Series Connecting And Operating Instructions
Safety light curtain (58 pages)
Security Sensors Leuze electronic SD4T 14 Connecting And Operating Instructions
Safety light curtain (73 pages)
Security Sensors Leuze electronic CML 720i Ex Operating Instructions Manual
Measuring light curtain (141 pages)
Security Sensors Leuze electronic ERS200-M0C3-M20-HLR Operating Instructions Manual
Safety command devices (43 pages)
Security Sensors Leuze electronic CRT448 Quick Start Manual
Color sensors (6 pages)
Security Sensors Leuze electronic OPSL 775 Manual
Laser edge detector (12 pages)
This manual is also suitable for:
Mld 500
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the MLD 300 and is the answer not in the manual?
Questions and answers