Leuze electronic CML 720i Ex Operating Instructions Manual page 74

Measuring light curtain
Table of Contents

Advertisement

Parameter
Start beam of blanking
area 1
End beam of blanking
area 1
Logical value for blanking
area 2
Start beam of blanking
area 2
End beam of blanking
area 2
......
......
Logical value for blanking
area 4
Start beam of blanking
area 4
End beam of blanking
area 4
Teach settings (group 9)
In most applications, it is recommended that teach values be stored in non-volatile memory
(remanent).
Depending on the function reserve selected for the teach event, the sensitivity is higher or lower
(high function reserve = low sensitivity; low function reserve = high sensitivity).
Parameter
Teach settings
Type of storage for teach
values
Sensitivity adjustment for
teach event
Leuze electronic
Index
Sub-
Data type
index
76
4
unsigned 16
(bit
offset
= 160)
76
5
unsigned 16
(bit
offset
= 160)
76
6
unsigned 16
(bit
offset
= 128)
76
7
unsigned 16
(bit
offset
= 112)
76
8
unsigned 16
(bit
offset
= 96)
....
....
....
....
76
12
unsigned 16
(bit
offset
= 32)
76
13
unsigned 16
(bit
offset
= 16)
76
14
unsigned 16
(bit
offset
= 0)
Index
Sub-
Data type
index
79
0
record 32 bit,
isolated
access to
sub-index not
possible
79
2
unsigned 8
(bit
offset
= 16)
79
3
unsigned 8
(bit
offset
= 8)
Starting up the device - IO-Link interface
Access
Value range
Default Explanation
RW
1 ... 1774
1
RW
1 ... 1774
1
RW
0 ... 4
0
RW
1 ... 1774
1
RW
1 ... 1774
1
..
..
..
..
..
..
RW
0 ... 4
0
RW
1 ... 1774
1
RW
1 ... 1774
1
Access Value range
Default Explanation
RW
RW
0 ... 1
0
RW
0 ... 2
0
CML 720i Ex
0: No beams blanked
1: Logical value 0 for blanked beams
2: Logical value 1 for blanked beams
3: Logical value = same as adjacent beam with
lower beam number
4: Logical value = same as adjacent beam with
higher beam number
.......
.......
0: No beams blanked
1: Logical value 0 for blanked beams
2: Logical value 1 for blanked beams
3: Logical value = same as adjacent beam with
lower beam number
4: Logical value = same as adjacent beam with
higher beam number
0: Non-volatile storage of teach values
1: Teach values stored only while voltage is ON
Sensitivity of the measurement system:
0: High function reserve (for stable operation)
1: Medium function reserve
2: Low function reserve
74

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents